480-Watt Intelligent DIN Rail Power Supply with Battery Back Up (UPS Function)
DRS-480
The MEAN WELL DRS-480 series DIN rail UPS power supplies have a full range universal AC input, making them ideal for OEMs producing equipment for global markets.
In addition to the primary output, there is an additional charging output that will automatically adjust the current depending on the primary output current. Should the AC mains fail, the DRS-240 will switch to powering the load from the back-up battery. When the AC mains is restored, the power supply will revert to powering the load from the mains supply and will recharge the battery.
The power supplies are suitable for charging lead-acid and lithium-ion batteries. To allow for remote monitoring, alarm signals are provided for AC Fail, Battery Low, Charger Fail, and DC OK. You can also opt for either a built-in MODBus or CANBus interface for remote status monitoring and control. With the CANBus version you can also set the output charging curve, charging voltage, and charging current via the MEAN WELL SBP-001 battery charger programmer (ordered separately).
The DRS-240 series power supplies have a wide operating temperature range (refer to derating curve in data sheet), making these power supplies suitable for a wide range of applications.
Refer to table below for models in the range:
Images are for reference only, refer to product data sheet
Models in this series
Output |
Input |
||||
---|---|---|---|---|---|
DC Voltage | Power | Rated Current | Input Efficiency | Input Voltage | |
DRS-480-24 (MODBus) | 24V | Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s. | 20A | 92.50% | 90 ~ 305VAC |
DRS-480-24CAN (CANBus) | 24V | Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s. | 20A | 92.50% | 90 ~ 305VAC |
DRS-480-36 (MODBus) | 36V | Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s. | 13.3A | 93.50% | 90 ~ 305VAC |
DRS-480-36CAN (CANBus) | 36V | Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s. | 13.3A | 93.50% | 90 ~ 305VAC |
DRS-480-48 (MODBus) | 48V | Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s. | 10A | 93.50% | 90 ~ 305VAC |
DRS-480-48CAN (CANBus) | 48V | Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s. | 10A | 93.50% | 90 ~ 305VAC |